Twin Power and Data Cable
Twin Power and Data Cable

Two different conductor types are used. A power pair(red/blue) is provided in 16 strands x 0.2mm (0.5mm”)for use where higher than normal current carrying capacity or lower voltage drop is required. he data cores consist of the standard strands x 0.2mm tinned copper wire.The data cores re aluminium foil wrap screened (with an earth drain
wire) to give added protection against inducedtransients thatmay be carried via the power cores or
outside influences.
Core Type Annealed tin copper
Strand Diameter 0.2mm
Strands per core 16 Power, 7 Data
Nom. Conductor Area 0.50mm² - Power, 0.22mm² - Data
Core Gauge 22 AWG
Insulation Thickness 0.4mm
Max operating Voltage 50v RMS
Current rating per core @ 70°C 3 AMP
Max Operating temperature 70°C
Nom Core Resistance @ 20°C 40 OHMS/KM
BS Standards BS4737, Section 3.30